KYN Metal Clad Switchgear Medium Voltage Solutions
Model: KYN28-24, KYN28A-24, KYN28-12, KYN61-40.5
Category: Automatic/Industrial Machines & Equipments / Industrial Machines / Electrical Power Machinery
Characteristics
Rated Voltage 12-40.5kV
Three phase AC 50/60Hz
metal modular assembly structure
compact and insulation design
Specifications
As a professional Metal Clad Switchgear Manufacturer in China, Liyond provides a comprehensive range of reliable KYN Metal Clad Switchgear for medium voltage power distribution systems. Our product portfolio includes the popular KYN28-12, KYN28-24, KYN28A-24, and the higher voltage KYN61-40.5 models. All our switchgear units feature a robust metal-clad design, ensuring maximum operational safety, system reliability, and ease of maintenance.
KYN28 Series Metal Clad Switchgear (e.g., KYN28-12, KYN28-24, KYN28A-24):
- These highly reliable models are the backbone of medium voltage secondary distribution, typically rated for 12kV and 24kV systems.
- They utilize air-insulated technology, a fully assembled structure, and are equipped with a dependable mechanical interlock system. This mechanism effectively prevents human error, guaranteeing grid safety.
- As a trusted medium voltage switchgear manufacturer, our KYN28 series switchgears are the ideal choice for power, metallurgy, petrochemical, and other key industries due to their superior anti-misoperation performance and modular design.
KYN61-40.5 Metal Clad Switchgear:
- The KYN61-40.5 is specifically engineered for higher voltage applications, suitable for 40.5kV power systems.
- It inherits the core safety features and metal-clad structure of the KYN series but offers enhanced insulation strength and breaking capacity.
- It provides a powerful and reliable solution for generator main feeders, large industrial feeders, and substation primary equipment.
To ensure you select the correct KYN Switchgear product for your project, please provide the following key details:
Rated Voltage: Specify the required voltage level for your system (e.g., 12kV, 24kV, 40.5kV).
Rated Current and Short-Circuit Breaking Capacity: Provide the main busbar rated current and the required fault breaking capability (e.g., rated short-time withstand current).
Configuration Requirements: Indicate the required cubicle circuit scheme (e.g., incoming, outgoing, metering, PT cubicle, etc.) and any special functional configuration needs.