Hipot Tester
Model: VITREK
Category: Automatic/Industrial Machines & Equipments / Testing Equipment / Inspecting/Measuring Instrument and Parts
Characteristics
Highest Level of Operator Safety V include: GFI earth ground leakage faults, SFI™ Safety Fault Interlock, TLSS™ Test Lead Safety Sense V continuously verifying proper connection of test leads prior to and during HV testing
High Power Output V With up to 50mA of sourcing current for DC hipot, gets heavy duty jobs done fast V available 100mA & 200mA AC drive requirements
Wide Range of Voltage Capabilities V Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up to 30KV RMS AC with external option
The Fastest Hipot Testers available V provide Ramp rates up to 50KV/second, dwell times as low as 20mS and overall test times as fast as 3mS in optional Flash mode
4-Wire Milli-Ohmmeter Function provides fast, accurate 5 digit resistance measurements with resolution down to 100µ[ and range up to 100k[
Built-in Phase Angle Measurement V allows the measurement and display of both resistive (in-phase) leakage current and reactive (out-of-phase) leakage current caused by capacitive coupling
Multi-Dwell Functionality V permits dwells at different voltage levels without having to return to zero between test steps V dramatically simplifying advanced analysis of dielectric properties
Ramp High/Dwell Low Current Limits V permits the user to set separate limits for the ramp and dwell providing faster ramp times and lower leakage test limits
Ethernet, RS232, Digital I/O, USB Printer & Scanner Control V All Standard Interfaces V Provides the highest level of test automation. GPIB optional
High Voltage Scanner Control V up to 256 point switching capability with available 964i HV Scanners.
Dual Dimensional / Test Specific / Broadband Arc Detection. Where lesser testers allow you to set a single, global, amplitude only arc limit V the technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test
Pico-Amp Leakage Measurement insures that even the lowest leakage current levels are accurately detected and tera-ohm range IR readings are stable and precise
Test Specific Fixture & Cable Compensation V Automatically calibrate out offset errors caused by lead resistance, fixture capacitance and leakage
Multi-Mode IR V Insulation Resistance values up to one Tera-ohm can be obtained with precision in your choice of 3 IR test modes V end on time, end on pass or end on fail
Capacitance Test Modes V provide tightly controlled charge and discharge profiles for superior results on critical solar panel tests and other highly capacitive loads
400Hz AC Voltage Withstand Testing for avionic component analysis
Safety Tested per EN 61010-1. EMC compliant to EN 61326-1