Our Products
Contact Information
10F., No.123-3, Sing-De Rd., San-Chong Dist., New Taipei City 241, Taiwan
Tel: 886-2-85123185
Fax: 886-2-85123186
On Line UPS
Model: LVP Series
Category: Automatic/Industrial Machines & Equipments / Industrial Machines / Electrical Power Machinery
Characteristics
# True Sine Wave Double Conversion UPS
# Smart Battery Charger Design
# 0.8 Output Power Factor
# Wide Input Voltage Range
# 50/60Hz Frequency Converter Mode
# Programmable Output Socket
Specifications
|
Model |
LVP-1000 |
LVP-1500 |
LVP-2000 |
LVP-3000 |
LVP-6000 |
LVP-10000 |
||||||
|
Capacity |
800W |
1200W |
1600W |
2400W |
4800W |
8000W |
||||||
|
Input |
Low Line Transfer |
160VAC±5% or 80VAC±5%@100% Load 110VAC±5% or 50VAC±5%@50% Load |
176VAC±3%@100% Load 110VAC±3%@50% Load |
|||||||||
|
Low Line Comeback |
175VAC±5% or 85VAC± 5%@100% Load |
186VAC±3%@100% Load 120VAC±3%@50% Load |
||||||||||
|
High Line Transfer |
300VAC ± 5% or 150VAC ± 5% |
300VAC±3% |
||||||||||
|
High Line Comeback |
290VAC ± 5% or 145VAC ± 5% |
290VAC±3% |
||||||||||
|
Frequency Range |
40Hz ~ 70Hz |
46~54Hz or 56~64Hz |
||||||||||
|
Power Factor |
>= 0.99 @ Nominal Voltage (Full Load) |
>= 0.99 @ 100% Load |
||||||||||
|
Output |
Output Voltage |
208 / 220 / 230 / 240VAC or 110 / 115 / 120 / 127VAC |
208 / 220 / 230 / 240VAC |
|||||||||
|
AC Voltage Regulation |
± 3% (batt. mode) |
± 1% (batt. mode) |
||||||||||
|
Frequency Range (synchronized range) |
47 ~ 53Hz or 57 ~ 63Hz |
46 ~ 54Hz or 56 ~ 64Hz |
||||||||||
|
Frequency Range (batt. mode) |
50Hz ± 0.25Hz or 60Hz ± 0.3Hz |
50 ± 0.1Hz or 60 ± 0.1Hz |
||||||||||
|
Current Crest Ration |
3 : 1 |
|||||||||||
|
Harmonic Distortion |
<= 3% THD (linear load) <= 6% THD (non-linear load) |
<= 4% THD (linear load) <= 7% THD (non-linear load) |
<= 3% THD (linear load) <= 6% THD (non-linear load) |
|||||||||
|
Transfer Time |
AC Mode to Batt. Mode : 0ms |
|||||||||||
|
Inverter to Bypass : 4ms (typical) |
0ms |
|||||||||||
|
Waveform (batt. mode) |
Pure Sine Wave |
|||||||||||
|
Efficiency |
AC Mode |
85% |
88% |
89% |
||||||||
|
Battery Mode |
83% |
88% |
||||||||||
|
Alarm |
Battery Mode |
Sounding every 4 seconds |
||||||||||
|
Low Battery |
Sounding every second |
|||||||||||
|
Overload |
Sounding twice every second |
|||||||||||
|
Fault |
Continuously sounding |
|||||||||||
|
Indicator |
LCD Display |
UPS status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault |
||||||||||
|
Battery (Standard Model) |
Battery Type |
12V / 7AH |
12V / 9AH |
12V / 7AH |
12V / 9AH |
12V / 7AH |
12V / 9AH |
|||||
|
Numbers |
3 |
3 |
6 |
6 |
20 |
20 |
||||||
|
Recharge Time |
4 hours recover to 90% capacity |
7 hours recover to 90% capacity |
9 hours recover to 90% capacity |
|||||||||
|
Charging Current |
1.0A (max) |
|||||||||||
|
Charging Voltage |
41.0VDC ± 1% |
82.1VDC ± 1% |
273.0VDC ± 1% |
|||||||||
|
Battery (Long-run Model) |
Battery Type |
Depending on applications |
||||||||||
|
Numbers |
3 |
3 |
6 |
6 |
18-20 |
|||||||
|
Charging Current |
8.0A (max) |
4.0A (max) |
||||||||||
|
Charging Voltage |
41.0VDC ± 1% |
82.1VDC ± 1% |
273.0VDC ± 1% |
|||||||||
|
Communication |
RS-232 or USB |
Support WIN 2000/2003/XP/2008/7 , Linux , MAC |
||||||||||
|
SNMP (optional) |
Power management from SNMP manager and web browser |
|||||||||||
|
Environment |
Humidity |
20 ~ 90% RH @ 0~40゚C (non-condensing) |
||||||||||
|
Noise |
Less than 45dB at 1M |
Less than 55dB@1M |
Less than 58dB@1M |
|||||||||
|
Dimension |
Standard Model (DxWxH) |
397 x 145 x 220mm |
421 x 190 x 318mm |
592 x 250 x 576mm |
||||||||
|
Long-run Model (DxWxH) |
397 x 145 x 220mm |
421 x 190 x 318mm |
592 x 250 x 576mm |
|||||||||
|
Net Weight |
Standard Model |
13kgs |
14kgs |
26kgs |
28kgs |
81kgs |
83kgs |
|||||
|
Long-run Model |
7kgs |
7kgs |
13kgs |
13kgs |
25 kgs |
27kgs |
||||||
Featured products